Cover

where cminb — diameter of bar. Assume 32 mm bars and 8 mm links

— say 25 mm cmindur — minimum cover due to environmental conditions. Assume XC1.

cnom= 35 mm to links

Figure 5.3

Perimeter column (internal environment)

Figure 5.3

Perimeter column (internal environment)